About Safety relay for safety products
AWAX 26XXL - SAFETY RELAYS - SELF CHECK BOX
Sensor controller on Acotom process / mechanical switches / emergency stops
Output contacts 8A/250V
Anti-gluing control of the reset button
Ultra-fast "DLC" short-circuit check : Short-circuit detection in 2 AAs, self-resetting
Safety management in a compact 22.5 mm format
12V version for embedded applications
Performance level with AWAX controller: PL = e
Safety category: 4
Safety Integrity Level: SIL 3
AWAX26XXL : Safety/diagnostic contacts: 3x NO 8A/250V redundant / 1x NF 8A/250V serial (XXL version) or parallel (XXLP version)
AWAX26XXLT6 : Safety/diagnostic contacts: 3x NO 6A/250V redundant / 1x NC 6A/250V redundant serial (XXL version) or parallel (XXLP version)
Time before dangerous failure: MTTFd = 415 years
Cycle before dangerous failure: B10d=100,000 at 5A
Risk duration: 20 ms max.
Cable severing protection: yes (opening of safety lines)
Short-circuit and overload protection: yes, using DLC (opening of safety lines and current limiting in contacts)
Reaction 2 AAs ultrafast
Indicators: 3 LEDs for diagnostics
Reset: configurable by dip-switch (SR=Automatic, N=manual)
Mounting: symmetrical DIN 35mm rail on DIN 50022
Mounting: IP 20 electrical box
Electrical connection: Maximum 14 AWG (2.08 mmAA2) / 250V minimum
Temperature: -20AAC to +60AAC
Certification: TAAV Rheinland 01/205/5168/11
UL 508 / C22.2 no.14 C-UL-US listed 34CB (file E214209)
Reliable Industrial Safety SolutionThe safety relay offers exceptional performance for machinery safeguarding, featuring approvals from CE and cULus and meeting rigorous international safety standards. Its compact DIN rail mount design is ideal for modern control panels, providing flexible installation in limited spaces without compromising on safety or reliability. Operators benefit from quick operation, simple diagnostics via LED indicator, and dual channel support.
Robust Environmental and Electrical EnduranceDesigned for challenging environments, this relay resists vibration (10-55Hz) and shock up to 10G, with an operational temperature range from -25C to +55C. Its enclosure achieves IP20 protection, safeguarding internal components against dust and accidental contact. With a mechanical life span of up to 10 million operations and high insulation resistance, it delivers lasting performance.
FAQ's of Safety relay for safety products:
Q: How does the safety relay enhance machine safety in my application?
A: The safety relay offers reliable monitoring and quick response (under 20ms) for critical functions like emergency stops and safety gate controls, ensuring machinery stops promptly when hazards are detected. This mitigates risks to operators and maintains compliance with international safety regulations.
Q: What are the benefits of DIN rail mounting for this relay?
A: DIN rail mounting provides fast, standardized installation and secure placement within control panels. The slim, standard-sized design optimizes panel space and simplifies wiring, especially valuable in industrial environments where other equipment may be closely packed.
Q: When should I use single channel versus dual channel input on this relay?
A: Single channel input is suitable for basic safety circuits, while dual channel input is recommended when higher safety integrity is required, such as monitoring redundancy in emergency stop or light curtain applications. Dual channel support helps detect wiring faults and enhances system safety.
Q: Where is this safety relay most effectively deployed?
A: This relay is perfect for industrial automation and machinery, particularly in France, as a distributor, exporter, importer, supplier, or trader. Its applications include emergency stop circuits, safety doors, and light curtains wherever fail-safe operation and compliance with CE and EN standards are needed.
Q: What is the process for wiring and setting up the relay?
A: The relay features screw terminals compatible with wire sizes up to 2 x 2.5mm2 (AWG14). Supply voltage is applied to terminals A1 and A2, and wiring diagrams are usually provided by the manufacturer to ensure correct installation for both single and dual channel inputs.
Q: How does the relay indicate operational status?
A: It integrates an LED indicator on the enclosure, giving immediate visual confirmation of the relay's status. This aids maintenance personnel in quickly assessing functionality and troubleshooting issues without specialized instruments.
Q: What are the advantages of its environmental resistance specifications?
A: With operation possible in temperatures from -25C to +55C, high shock and vibration resistance, and IP20 enclosure protection, this relay is suitable for tough industrial environments. It reliably operates in conditions with dust, vibration, and mechanical stress, ensuring long-term performance.